AN INDEPENDENT KNOWLEDGE PUBLICATION Our editorial approach ↗
BatteryPassport.digital Search guides /
Menu & topics
Stationary storage & BESS

BESS scope and categories

BESS scope covers stationary storage systems that are industrial batteries, with the category, capacity, chemistry, and application recorded before any passport or safety decision.

GUIDE / STATIONARY STORAGE & BESSIDENTITY → INFORMATION → EVIDENCE

BESS scope covers battery energy storage systems used for stationary storage, which are commonly industrial batteries under Regulation (EU) 2023/1542, with the category, capacity, chemistry, and application recorded before any passport or safety decision is made. BESS is a system description, not a battery category in the Regulation, and a BESS can be built from new cells, from new modules, or from repurposed EV modules, each with different record consequences. The record must state whether the system is a single industrial battery, an assembly of batteries, or a battery incorporated in equipment, and must state the capacity, the chemistry, and the intended stationary application. A scope statement that calls every storage system a BESS, without a category and capacity decision, cannot answer whether a passport is required.

BESS means a battery energy storage system for stationary use, including the battery, the battery management system, power conversion, and controls as installed. The scope in this record is the battery part of the system as defined in Article 3, for the application stated.

How is the stationary category decided?

BESS scope and categories applies within that frame, and the record should not borrow an EV battery rule without checking whether the article applies to industrial batteries. Articles 3 and 77 is the operative provision for the point in question. A developer scoping a grid scale storage project with containerised batteries should record the category decision, including the capacity calculation and the date, because the threshold decision decides whether a passport is required. A container with 2 MWh of lithium iron phosphate batteries should be recorded as an industrial battery system over 2 kWh, with the capacity calculation, the module and system boundaries, and the application stated before the passport is built.

How is the record built in layers?

For BESS scope and categories, each layer should name its source, its date, and its owner. The category decision, capacity calculation, and system boundary note should be tied to the identifier, so a maintenance entry, a commissioning test, and a passport entry refer to the same system. Stationary storage with exclusively external storage follows a different carbon footprint timetable under Article 7, and the record should state whether the system is external storage or not, with the reason, rather than assume the general timetable.

How is performance measured in service?

For BESS scope and categories, the record should state the capacity test method, the temperature range, the charge and discharge rates, the depth of discharge, and the end of life criterion used for a durability statement. A developer scoping a grid scale storage project with containerised batteries should name the standard or method used for each value and should not present a laboratory value as a site value without stating the difference. A container with 2 MWh of lithium iron phosphate batteries should be recorded as an industrial battery system over 2 kWh, with the capacity calculation, the module and system boundaries, and the application stated before the passport is built.

How is safety information recorded?

For BESS scope and categories, the record should state the safety tests applied, the battery management system functions that protect the system, the ventilation or enclosure requirements, and the instructions given to the site operator. The category decision, capacity calculation, and system boundary note should include the test reports, the installation instructions, and the handover of safety information, each dated. Stationary storage with exclusively external storage follows a different carbon footprint timetable under Article 7, and the record should state whether the system is external storage or not, with the reason, rather than assume the general timetable.

How are installation and maintenance recorded?

For BESS scope and categories, the commissioning record should state the installer, the date, the tests passed, the settings applied, and any deviations from the design. A developer scoping a grid scale storage project with containerised batteries should ensure that maintenance entries update the passport or the linked record where the Regulation requires an update, and that earlier entries are preserved. A container with 2 MWh of lithium iron phosphate batteries should be recorded as an industrial battery system over 2 kWh, with the capacity calculation, the module and system boundaries, and the application stated before the passport is built.

How are transfer and end of life decisions recorded?

For BESS scope and categories, a transfer of ownership, a change of application, a repurposing of EV modules into stationary service, or a move to recycling each needs a dated entry, a named operator, and a statement of what was transferred. The category decision, capacity calculation, and system boundary note should include the state of health assessment, the safety checks applied, and the new application, where a second life use is claimed. Stationary storage with exclusively external storage follows a different carbon footprint timetable under Article 7, and the record should state whether the system is external storage or not, with the reason, rather than assume the general timetable. A developer scoping a grid scale storage project with containerised batteries should check the passport or linked record at transfer, record any gap found, and give the gap an owner and a review date.

How is scope decided for a hybrid storage project?

Scope for a hybrid project, such as batteries paired with solar or with a generator, starts with the system boundary: the battery, the power conversion, the controls, and the enclosure are listed, and the battery part is identified as the industrial battery. A worked scope note for a solar paired container shows the battery capacity, the chemistry, the application, and the boundary, with the solar and generator parts marked as outside the battery record. The capacity is calculated for the battery alone, not for the hybrid output, and the threshold decision follows that figure. A scope note that counts the whole hybrid output as battery capacity overstates the battery and misstates the threshold, so the boundary note is filed with the capacity calculation.

System elementCategory questionRecord
Battery modulesIndustrial battery, capacityCapacity, chemistry, identifiers
Power conversionEquipment, not a batterySystem boundary note
Controls and enclosurePart of the system as installedConfiguration record, date

Scope decides every later duty, and a scope decision that is not written down will be remade, differently, at each later stage of the project.

Sources & further reading

Source links point to primary materials and further reading, including commercial implementation resources where cited. This introductory guide does not replace the legislation.